Burke Lockable Dowel

Reinforcement Detail

Local reinforcement is required around each Burke Lockable Dowel to guarantee that the forces are transferred between the connectors and the concrete. Correct detailing in accordance with appropriate design codes and the recommendations provided here will ensure the dowels attain their full capacity. The tables show the main reinforcement required, together with details of reinforcement above and below the connectors. Although only the sleeve components are illustrated, the same reinforcement is required around the dowel component.

Reinforcement-Detail-ChartsReinformcement-Detail